Grease Traps & Interceptors
home : products : contact : site map
register : login
Go
     

Grease Traps & Interceptors

Grease Traps & Interceptors - Accepta’s range of high performance stainless steel grease traps and interceptors have been developed to significantly improve the performance of domestic, commercial and industrial drainage systems by minimising the problems caused by the unwanted accumulation of waste solids, grease and fats. Constructed from high quality stainless steel Accepta’s grease traps and interceptors incorporate an innovative high performance mesh system that acts to effectively filter out solid organic waste before it enters the drainage system, minimising its impact on drains, pipes, interceptors and wastewater discharge quality.

Performance Benefits

Accepta’s high performance grease traps and interceptors offer a number of significant benefits including:

    • Minimise disruption and drain cleaning call-out charges.
    • Better environmental performance - improved wastewater discharge quality.
    • High performance stainless steel mesh system to filter out soild organic waste.
    • Eliminate unwanted odours.
    • Easy to maintain - quick and easy to inspect and clean with quick release watertight lid and lift-out filter basket.
    • Durable corrosion free, high quality stainless steel (type 304) construction with fully welded seams for improved strength and durability.
    • Can be used either internally or externally.
    • Easy installation – uses standard “Multifit” connections.
    • 2 year warranty.

Applications

Accepta Grease Traps & Interceptors

Accepta’s range of grease and fat traps are suitable for most domestic, industrial and commercial applications including:

    • Restaurants.
    • Hotels and guest houses.
    • Pubs, bars and cafes.
    • Commercial kitchens.
    • Fast food restaurants and takeaways.
    • Bakeries.
    • Food processing.
    • Hospitals and healthcare facilities.
    • Manufacturing operations.
    • Industrial process applications.
    • and many more…

What Size do I Need?

To select the correct trap for your needs use the diagram and sizing chart below, or contact Accepta on +44 (0) 161 877 2334 or e-mail info@accepta.com for specialist advice.

 

sizing chart 1

How do they Work?

Accepta’s high performance filtration system which is an integral component of each unit removes most solid matter from the wastewater before it enters the drainage system. As the wastewater enters the trap, lighter grease, fats and oils separate and float on the water, whilst solid particles settle to the bottom of the filter cassette. As the wastewater drains, it is drawn through the filter cassette, which helps to reduce any turbulence and filters out even more solid waste material. The wastewater is then drawn up through the integrated air trap into the main drainage system.

Maintenance

The cleaning cycle will depend on the volume of material running through the filter. Cleaning operations should be carried out only when the trap is cold. We generally recommend that the filter is cleaned at the start of each working day, after the grease and fat deposits have solidified overnight.

Cleaning

The cleaning cycle depends on volume of use. Cleaning should only be carried out at the start of the working day when system is cold. The suggested cleaning procedure is as follows:

Stage 1 - Unclip the lid, remove lid, wipe the lid clean and set aside.

Stage 2 - Using a sieve skim out accumulated grease and fat.

Proceed to Stage 5 if using the Accepta7141 and dosing system.

Stage 3 - Open low level drain valve (if fitted) and drain the unit.

Stage 4 - Close low level drain valve (if fitted).

Stage 5 - Lift out filter cassette (basket), empty and clean.

Proceed to Stage 7 if using Accepta 7141 and dosing system.

Stage 6 - Flush out the unit with hot soapy water.

DO NOT use bleach products if using Accepta 7141.

Stage 7 - Refit the filter cassette (basket).

Stage 8 - Replace the lid, clips, closing the side clips first, and then the clips at the pipe ends.

Automatic Dosing System

Accepta recommend that their stainless steel filtered grease traps and interceptors are used in conjunction with Accepta 7141 (bio cleaner) and their dosing system. This significantly improves operational efficiency and has several significant benefits. Either mains or battery operated, Accepta’s dosing system automatically dispenses a measured amount of Accepta 7141, either manually or automatically at preset times – normally after hours, when the grease and fat deposits have solidified.

Additional Information & Technical Support

For further information, technical support and advice please call Accepta on +44 (0) 161 877 2334 or e-mail info@accepta.com. For additional products, specifications, product data and MSDS's please review our products pages.

 

 

 

Home  |  Products  |  About |  Advantage |   Technical  |  Knowledge  |  FAQs  |  Help  |  ContactMSDS
Privacy |  Facts  |  Media  |  Newsletter  |  Terms  |  Disclaimer  |  Chlorine Dioxide  |  Site Map
©2007 Accepta Water Treatment
Home Products Advantage About Us Technical Knowledge FAQs Help Contact Us